The AC EVSE © tester for automatic or manual monitoring and analysis of all loading operations at AC charging stations (EVSE) according to established standards.

2014-09-AC-03-web

 

2013-09-08-AC-Tester04b

The EVSE-Tester© was developed to check the complex issue of charging of electric vehicles. With the EVSE tester © it is possible to simulate the multiple electric vehicle models to test a wide variety of charging facilities.
The EVSE-Tester © can be used for fully automatically or manually standardized test cases for checking charging stations.
During the test phase, the EVSE-Tester can charge a charging station with up to 1 kW.
An integrated oscilloscope allows the analysis of the CP, L1, L2 and L3 voltage.
All test results are automatically saved in a PDF protocol file.
So, the EVSE-Tester© is a valuable tool to ensure a reliable and error-free operation of charging stations.
The EVSE-Tester © is equally suitable for use in development and production of charging stations, as well as for verification of charging stations in the field, eg by service workshops.
Manual EVSE-Tester

FEATURES
- PLC-test according to ISO 15118: 2013 and DIN 70121:2012
- Complete V2G-Cycle. SECC
- SLAC Test
- All tests are individually adjustable

PWM
- EVSE response to different PWM voltage level
- EVSE PWM frequency measurement
- EVSE PWM duty cycle measurement
- Additional analysis of the PWM signal via integrated oscilloscope

Charging voltage
- Measuring of the charging voltage L1, L2 and L3 or DC
- Measuring of the angle of rotation of the charging voltage L1, L2 and L3
- Measurement of the PP-resistance
- Examination of the charging station under load through built-in load resistors
- Automatic cut off if overcurrent and overheating of the load resistors

Case
- Charging plug IEC 62196 Combo Type 2 (AC and DC)
- Compact design and integrated battery makes mobile use possible
- Controlling of the EVSE Tester © via a built-in PC with LCD touch screen
- Storageing of all test results in a log file PDF

 

2013-09-08-EVSE-Tester13d

 

2014-03-12-Tracer-BMWi3-30-altran03-web

 

Technical Data

Device Power Supply

90 - 260 VAC

Power consumption

approx. 20 W

Build in accumulator

12V 3,4 Ah

Operation time accumulator

approx. 1,5 h

Operating temperature

0 - 40 C

Storage temperature

-10 - 60 C

Relative Humidity

15% - 70% (non-condensing)

Connection to charging device

Combo Typ 2 (IEC 62196)

Charging test consumption

max. 1 KW

Display

LCD, LED, 8,2“, Touch sensitive, 800 x 600 Pixel

Mass storage

SSD-120 GByte, 2 GByte RAM

Cooling

Passiv

Operation system

Windows 7 Professional

Standardize

ISO/IEC 15118, ISO/IEC 61851, IEC 62196, DIN 70121

PWM/PLC-Module

1 x hse-electronics EVC Kit
1 x QCA-7000 Chipset
PWM Measuring range: -30 to +30 V
PWM amplitude: 3-12V adjustable
PWM analysis: frequency and duty cycle

Software

Automatic test with V2G implementation
PWM control and analysis software
oscilloscope software

Case connectors

1 x USB 2.0

Dimensions

b: 34 cm; h: 41 cm; t: 36 cm

Case-Material

Aluminium

Weight

8 Kg

links-electronics05
oben08

f_germany 

 deutsch

 

 

 

 